IBM DS3200 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Matrizes de discos IBM DS3200. IBM DS3200 User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 144
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1

System Storag e DS3200 Sto rage Subsys temInstallation, User’s, and Maintenance Guide

Página 2

50. Removing a battery unit from the controller ...8851. Memory cache DIMM location ...8952. Removing a contr

Página 3

9. When reconstruction is finished on the new drive, repeat step 5 on page 81through step 8 on page 81 for each additional drive that you want to inst

Página 4 - Sixth Edition (October 2009)

is optimal (no overheating has occurred, all electrical receptacles are working, andso on). For more information, see “Restoring power after an unexpe

Página 5 - Contents

labels on the power supply to mark the LEDs correctly. The label sheetcontains the peel-off labels that you actually place on the power supply.5. Usin

Página 6

DANGERWhen working on or around the system, observe the followingprecautions:Electrical voltage and current from power, telephone, andcommunication ca

Página 7 - Contents v

10. On the left side of the power supply, press the orange release tab to the rightjust enough to release the handle; then, rotate the handle downward

Página 8

v Make sure that the power cord is working and fully seated into the electricalreceptacle and the power supply ac connector.v Reinstall the power-supp

Página 9

4. Remove the controller from the chassis.a. On the left side of the controller, press the orange release tab to the rightjust enough to release the h

Página 10

8. Insert the controller into the chassis:a. Slide the controller into the empty controller bay in the storage subsystem.Make sure that the handle is

Página 11

2. Remove the controller from the chassis.a. On the left side of the controller, press the orange release tab to the rightjust enough to release the h

Página 12

4. Remove the DIMM from the connector.a. Wait 60 seconds before you proceed, to allow any residual charge to drainfrom the controller.b. Open the reta

Página 13

Tables1. Features and operating specifications...42. Software and firmware levels for the DS3200 storage subsystem ...1

Página 14

7. If you are installing the DIMM as part of replacing a controller, return to step 13on page 68. Otherwise, continue to step 8.8. Reinstall the batte

Página 15 - Safety xiii

Replacing the bezelsThe left bezel contains the LEDs; the right bezel contains the hard disk driveidentification information. See the illustrations in

Página 16

Replacing the release tab on a controller or power supplyThe miscellaneous hardware kit contains two replacement release tabs: one for apower supply a

Página 17 - Safety xv

4. Close the handle to move it out of the way.The following illustration shows how to remove the release tab on a powersupply.5. Use a #1 or #0 Philli

Página 18 - CAUTION:

The following illustration shows a drive compatibility key.To replace a drive compatibility key, complete the following steps:1. Read the safety infor

Página 19 - Chapter 1. Introduction

flush with the side wall, the tab is covered, and the front of the key extendsapproximately 1 mm [0.04 in.] in front of the short metal upper guide).6

Página 20 - Machine type, model, and

98 System Storage DS3200 Storage Subsystem: Installation, User’s, and Maintenance Guide

Página 21 - Chapter 1. Introduction 3

Chapter 6. Solving problemsThis chapter contains information to help you solve some of the simpler problemsthat you might have with the storage subsys

Página 22

Table 5. TroubleshootingProblemindicator Component Possible cause Possible solutionsAmber LED is lit Drive (drivefault LED)Drive failure Replace the f

Página 23 - Product updates

Table 5. Troubleshooting (continued)Problemindicator Component Possible cause Possible solutionsAmber and greenLEDs are litPower supply(fault andpower

Página 24 - Best practices guidelines

x System Storage DS3200 Storage Subsystem: Installation, User’s, and Maintenance Guide

Página 25 - System Storage

Table 5. Troubleshooting (continued)Problemindicator Component Possible cause Possible solutionsGreen LED isflashing slowly(once every 2seconds)Drives

Página 26 - Figure 4. Bezel (right side)

Table 5. Troubleshooting (continued)Problemindicator Component Possible cause Possible solutionsHard disk drive isnot visible in theStorage Managersof

Página 27 - Controllers

104 System Storage DS3200 Storage Subsystem: Installation, User’s, and Maintenance Guide

Página 28 - Power supply and fans

Chapter 7. Parts listing, DS3200 storage subsystemThe replaceable components that are available for the DS3200 storage subsystemare described in this

Página 29 - Battery units

Table 6. Parts listing for DS3200Index DescriptionCRU partnumber(Tier 1)CRU partnumber(Tier 2)FRUpartnumber1 Chassis and midplane assembly 39R65452 Be

Página 30 - Determining firmware levels

For units intended to be operated at 115 volts: Use a UL-listed and CSA-certifiedcord set consisting of a minimum 18 AWG, Type SVT or SJT, three-condu

Página 31 - Dimensions

Table 7. IBM power cords (continued)IBM power cord partnumber Used in these countries and regions39M5165 Chile, Italy, Libyan Arab Jamahiriya39M5172 I

Página 32 - Site wiring and power

Appendix A. RecordsWhenever you add optional devices to the DS3200, be sure to update theinformation in this appendix. Accurate, up-to-date records ma

Página 33 - Power cords and receptacles

Hard disk drive locationsUse Table 9 to keep a record of the hard disk drives that are installed in or attachedto the DS3200. This information can be

Página 34

Storage subsystem and controller information recordTable 10 provides a data sheet for recording storage subsystem names,management types, Ethernet har

Página 35 - Inventory checklist

SafetyBefore installing this product, read the Safety Information.Antes de instalar este produto, leia as Informações de Segurança.Pred instalací toho

Página 36 - Installation overview

Table 11 shows a sample information record. This network contains storagesubsystems that are managed by using both the direct-management andhost-agent

Página 37

Appendix B. Getting help and technical assistanceIf you need help, service, or technical assistance or just want more informationabout IBM products, y

Página 38 - Required tools and hardware

You can find service information for IBM systems and optional devices athttp://www.ibm.com/systems/support/.Software service and supportThrough IBM Su

Página 39 - Preparing the site

Appendix C. NoticesThis information was developed for products and services offered in the U.S.A.IBM may not offer the products, services, or features

Página 40

Adobe and PostScript are either registered trademarks or trademarks of AdobeSystems Incorporated in the United States and/or other countries.Cell Broa

Página 41 - SAS controller connectors

Some software might differ from its retail version (if available) and might not includeuser manuals or all program functionality.Particulate contamina

Página 42 - Working with SAS cables

3039 E. Cornwallis RoadP.O. Box 12195Research Triangle Park, North Carolina 27709-2195U.S.A.In the request, be sure to include the publication part nu

Página 43

European Union EMC Directive conformance statementThis product is in conformity with the protection requirements of EU CouncilDirective 2004/108/EC on

Página 44 - Blue plastic tab

IBM verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohneEmpfehlung der IBM gesteckt/eingebaut werden.EN 55022 Klasse A Geräte müssen

Página 45 - Redundant drive channel pair

IndexAac power LED 52ac power recovery 15ac power supply specifications 4accessible documentation 117activity LED, hard disk drive 53airflow 10, 15are

Página 46

Important:Each caution and danger statement in this document is labeled with anumber. This number is used to cross reference the English-languagecauti

Página 47

enclosure ID (continued)setting 24environmental specifications 4Ethernetcabling 19connection to management station 33connectors 9, 35Ffault LEDbattery

Página 48

notices (continued)FCC, Class A 118safety and caution xinotices and statements 3numbers, enclosure ID 9Ooperating specifications 4out-of-band manageme

Página 49

storage subsystem (continued)sample information record 112startup sequence 46troubleshooting 51turning off 55turning on 46storage subsystem configurat

Página 51

Part Number: 46M1392Printed in USA(1P) P/N: 46M1392

Página 52 - Important:

DANGERRack-mounted devices are not to be used as shelves or work spaces.(L002)Safety xiii

Página 53 - Controller A Controller B

DANGERMultiple power cords. The product might be equipped with multiple powercords. To remove all hazardous voltages, disconnect all power cords.(L003

Página 54

DANGERWhen working on or around the system, observe the following precautions:Electrical voltage and current from power, telephone, and communicationc

Página 55

CAUTION:or>18 kg (39.7 lb)or18-32 kg (39.7-70.5 lb)The weight of this part or unit is between 18 and 32 kg (39.7 and 70.5 lb). Ittakes two persons

Página 56 - Host system

Chapter 1. IntroductionThis chapter describes the operating specifications, features, and components ofthe IBM®System Storage™DS3200 storage subsystem

Página 58

To check for updates, complete the following steps:1. Go to http://www.ibm.com/servers/storage/support/.2. On the “Support for System Storage and Tota

Página 59

Use Table 9 on page 110 to keep a record of the hard disk drives that are installedin or attached to the DS3200. This information can be helpful when

Página 60

Features and operating specificationsTable 1 contains a summary of the features and operating specifications of theDS3200. Depending on your DS3200 mo

Página 61

Models and optional devicesThe DS3200 RAID controller cache size, partitions, and other features varydepending the DS3200 model and optional devices.C

Página 62

6. On the “My support” page, click the Edit profile tab; then, click Subscribe toemail.7. In the menu, select Storage.8. On the next page, select the

Página 63

v A storage subsystem in an optimal state should recover automatically from anunexpected shutdown and unattended simultaneous restoration of power tos

Página 64 - Hardware inspection

Bezel (left side)The left bezel contains the DS3200 LEDs, as shown in the followingillustration. For a description of the LEDs, see “Front LEDs” on pa

Página 65

Attention:1. After you remove a drive from a bay, wait 70 seconds to allow the drive to spindown before you replace or reseat the drive . Failure to d

Página 66

Figure 5 shows a single-controller DS3200 without the optional SAS host portadapter installed.Figure 6 shows a dual-controller DS3200 with the optiona

Página 67

Figure 8 shows the airflow through the storage subsystem.Battery unitsEach RAID controller contains 512 MB of cache memory (or more, if you haveupgrad

Página 68 - Firmware updates

System Storag e DS3200 Sto rage Subsys temInstallation, User’s, and Maintenance Guide

Página 69

Software and firmware support code upgradesTo enable support for the DS3200, you must make sure that your system softwareand firmware are at the level

Página 70 - Power-supply LEDs

Drive Enclosurev ESM firmware versionSpecificationsThe specifications of the DS3200 are listed in Table 1 on page 4. This sectionprovides additional s

Página 71 - Controller LEDs

Table 3. DS3200 weights (continued)DS3200WeightMaximum1Empty21Chassis with all components and 12 hard disk drives.2Chassis without components and hard

Página 72 - SAS link up

The agency ratings for the DS3200 storage subsystem are 6 amps at 100 V ac and2.5 amps at 240 V ac. These are the overall maximum operating currents f

Página 73

v To correct airflow in each rack, the rack filler plates must be installed in unusedpositions. Also, all the gaps in the front of the racks must be s

Página 74

Chapter 2. Installing the storage subsystemThis chapter provides the information about installing the storage subsystem into arack cabinet.Before you

Página 75

If an item is missing or damaged, contact your IBM marketing representative orauthorized reseller.Instructions for installing the DS3200 in a rack cab

Página 76

AttentionBefore you power-on the storage subsystem, it must contain at least fourdrives. If at least four drives are not installed in each attached st

Página 77

v While the device is still in its static-protective package, touch it to an unpaintedmetal part of the system unit for at least 2 seconds. This drain

Página 78

v Rack power jumper cords that come with the DS3200v Rack-mounting hardware that comes with the DS3200v SAS cables (1-meter or 3-meter)Preparing the s

Página 79 - Controller cache battery

Note: Before using this information and the product it supports, read the general information in Appendix C, “Notices,” on page 115and see the Warrant

Página 80 - Controller battery age timer

22 System Storage DS3200 Storage Subsystem: Installation, User’s, and Maintenance Guide

Página 81 - Removing a controller

Chapter 3. Cabling the storage subsystemAfter the storage subsystem is installed in its permanent location, you must cable itto hosts, drives, and oth

Página 82 - Installing a controller

Enclosure ID settingsThe controller automatically sets the enclosure ID number. You can change thesetting through the storage management software, if

Página 83

Attention: To avoid damage to the SAS cables, consider the followingprecautions:v When you route the cable along a folding cable-management arm, leave

Página 84 - Replacing a controller

To remove a mini-SAS cable, complete the following steps:1. Put one finger into the hole on the blue plastic tab on the mini-SAS connectorand gently p

Página 85

System Storage DS3000 Support CD. Incorrect drive migration might cause loss ofconfiguration and other storage subsystem problems. Contact your IBMtec

Página 86 - Memory cache battery

Overview of steps to connect storage expansion enclosures to astorage subsystemTo connect storage expansion enclosures to the storage subsystem, compl

Página 87

One single-controller DS3200 and one or more storageexpansion enclosuresTo cable one single-controller DS3200 to one or more single-ESM storageexpansi

Página 88

One dual-controller DS3200 and one storage expansionenclosureTo cable one dual-controller DS3200 to one storage expansion enclosure, connectthem as sh

Página 89 - Captive fasteners

One dual-controller DS3200 and three storage expansionenclosuresTo cable one dual-controller DS3200 and three storage expansion enclosures,connect the

Página 90

ContentsFigures ...viiTables ...ixSafety ...xiChapter 1. Introduction ...

Página 91

4. Power-on the storage expansion enclosure.5. Connect one end of a Serial Attached SCSI (SAS) cable to the Driveexpansion port on Controller A in the

Página 92 - Removing a hard disk drive

Upgrading a single-controller to a dual-controller when there is noattached EXP3000 enclosureIf you are upgrading a single-controller DS3200 storage s

Página 93 - Installing a hard disk drive

Important:1. To minimize security risks, do not connect the DS3200 to a public LAN or publicsubnet. Use a local private network for the DS3200 and the

Página 94

Connect an Ethernet cable from the management station to the Ethernet connectoron controller A on the rear of the storage subsystem. For a dual-contro

Página 95 - Replacing multiple drives

Host-agent (in-band) management methodThis method requires that host-agent software be installed on the host server. Thehost-agent software enables th

Página 96

Installing the storage subsystem configurationUsing the information from the previous sections, install the host systems and hostbus adapters (HBAs).N

Página 97

To connect a SAS host bus adapter (HBA) to the DS3200 storage subsystem,complete the following steps:1. Connect a SAS cable from the DS3200 RAID contr

Página 98

The following illustration shows a direct-attached SAS connection to dual HBAs in asingle-host (redundant host connection).The following illustration

Página 99

Direct-attached dual-controller connectionsThe following illustration shows a direct-attached SAS connection from eachcontroller to a single HBA in th

Página 100 - Replacing a power supply

The following illustration shows multiple redundant direct-attached SAS hostconnections. This configuration is also the configuration to use for a dua

Página 101

One dual-controller DS3200 and one storage expansion enclosure...30One dual-controller DS3200 and two storage expansion enclosures . . . 30One dual-c

Página 102

3. Install the IBM BladeCenter SAS Connectivity Modules in the I/O bays inBladeCenter unit. See the documentation that comes with the SAS connectivity

Página 103

Figure 32 shows an example of a DS3200 that is connected to one BladeCenterunit.Cabling the DS3200 power suppliesTo connect the DS3200 power-supply co

Página 104 - Guide pin

44 System Storage DS3200 Storage Subsystem: Installation, User’s, and Maintenance Guide

Página 105 - Replacing a battery

Chapter 4. Operating the storage subsystemThis chapter describes operating procedures for the DS3200.To ensure optimal operation of the storage subsys

Página 106

4. Use the Storage Subsystem Profile or DS3000 Profile to make sure that thefollowing functions are enabled:v For all DS3000 models, enable Media Scan

Página 107 - Host adapter or

The following procedure addresses two situations:v The entire storage subsystem has been shut down (the main circuit breakers forthe rack cabinet are

Página 108

each storage enclosure powers-on, the green and amber LEDs on the front andrear of the storage expansion enclosure turn on and off intermittently. The

Página 109 - Installing the DIMM

Before any planned system shutdown or after any system additions, removals, ormodifications (including firmware updates, logical drive creations, stor

Página 110

For example, the recovery procedure for a PFA flag (impending drive failure) on adrive varies depending on the drive status (hot spare, unassigned, RA

Página 111 - Installing the bezels

Attention: Failure to observe the limitations, prerequisites, sequences, anddependencies in the readme file might result in a loss of data access.Unle

Página 112

Replacing the drives one at a time...80Replacing a power supply ...82Replacing a battery ...87Repla

Página 113 - Release tab

Checking the LEDsThe LEDs indicate the status of the storage subsystem and components. GreenLEDs indicate a normal operating status; amber LEDs (needs

Página 114

Front LEDsThis section describes the primary LEDs and controls on the front of the DS3200storage subsystem.Power-on LED (green)When this green LED is

Página 115

If the optional SAS host port adapter is installed in the RAID controller, the host portadapter contains two additional SAS host connectors with LEDs.

Página 116

Turning off the storage subsystemThe DS3200 is designed to run continuously. After you turn it on, do not turn it off.Turn off the power only in the f

Página 117 - Chapter 6. Solving problems

Power-off overviewReview the following information before you continue with the power-offprocedure:Turn off the power to each device according to the

Página 118

c. When the recovery procedure is completed, click Recheck in the RecoveryGuru. This action runs the Recovery Guru again to make sure that theproblem

Página 119

v Yes: Do not continue with this procedure. Contact your IBM technical-supportrepresentative for assistance. Depending on the current service agreemen

Página 120

v An unusually high room temperaturev Fan failures in the power-supply unitsv Defective circuitry in a power supplyv Blocked air ventsv Failures in ot

Página 121

v No: Go to step 6.6. Turn off both power switches on the DS3200 (see Figure 33 on page 47) andthen power-off all connected storage expansion enclosur

Página 122

Cache memoryCache memory is memory on the RAID controller that is used for intermediatestorage of read and write data on the DS3200 RAID controllers.

Página 123 - Replaceable components

vi System Storage DS3200 Storage Subsystem: Installation, User’s, and Maintenance Guide

Página 124 - Power cords

If the battery fails the learn-cycle test, the battery fault LED is lit, indicating a batteryfault, and a Defect Battery error message is displayed in

Página 125

Chapter 5. Replacing componentsThis chapter contains information about replacing the storage subsystemcomponents. It also contains information about i

Página 126

3. Disconnect all attached interface cables from the failed controller. Be sure tolabel each cable so that you can reconnect it correctly.4. Remove th

Página 127 - Appendix A. Records

4. Start the command-line interface; then, enter the following command to changecontroller A from simplex (single-controller) mode to duplex (dual-con

Página 128 - Hard disk drive locations

12. Make sure that all storage expansion enclosure connections with each otherhave been completed (see the dual-controller topologies in “DS3200 stora

Página 129 - Appendix A. Records 111

5. Is the service action allowed LED lit?v Yes: Go to step 6.v No: Another component might require attention before you can remove thecontroller. Use

Página 130

11. Remove the battery from the failed controller.a. Turn the blue captive fastener counterclockwise until the battery can movein the direction that i

Página 131 - Using the documentation

19. Check the LEDs on the new controller to make sure that the controller is fullyoperational.20. Use the DS3000 Storage Manager Subsystem Management

Página 132 - IBM Taiwan product service

4. Remove the controller from the chassis.a. On the left side of the controller, press the orange release tab to the rightjust enough to release the h

Página 133 - Appendix C. Notices

7. Align the SAS host port adapter as shown in the following illustration. Securethe front end of the adapter to the controller with the two screws th

Página 134 - Important notes

Figures1. Example of DS3200 serial number label, product name, and machine type and model numberlocations ...22. DS3200

Página 135 - Documentation format

15. Verify the state of the LEDs on the newly inserted controller. See “ControllerLEDs” on page 53. You can also use the DS3000 Storage ManagerSubsyst

Página 136

AttentionBefore you power-on the storage subsystem, it must contain at least fourdrives. If at least four drives are not installed in each attached st

Página 137 - Appendix C. Notices 119

Removing a hard disk driveTo remove a hot-swap hard disk drive, complete the following steps.Note: The hard disk drive comes installed in a drive tray

Página 138

Installing a hard disk driveExcept during the DS3200 storage subsystem initial power-on, you can add harddisk drives while the storage subsystem is tu

Página 139

This includes transmission problems between the host controllers and the drives.This section explains how to replace a failed hard disk drive.Note: If

Página 140

8. Make sure that the drive is shown in the DS3000 Storage Manager SubsystemManagement window.Note: If you are replacing more than one hard disk drive

Página 141 - Index 123

v Which method most closely matches the recommended drive upgrade procedurethat is provided in the operating-system or storage-management softwaredocu

Página 142

Attention: When you handle static-sensitive devices, take precautions toavoid damage from static electricity. For details about handling static-sensit

Página 143

enclosures, turn on the power-supply switches on the rear of the storagesubsystem. You must turn on both power-supply switches to take advantage ofthe

Página 144 - (1P) P/N: 46M1392

Set the drives on a dry, level surface away from magnetic fields. Save thepacking material and documentation in case you have to return the drives.5.

Comentários a estes Manuais

Sem comentários