Ibm X.25 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Ibm X.25. IBM X.25 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1

IBM IBM ARTIC X.25 Interface Co-ProcessorPCI Adapter Guide to Operations

Página 2

Removal and Replacement Procedures ... 4-17Co-Processor Adapter Removal ... 4-18Co-Processor Adapter Replacement ...

Página 3

About This BookThis manual contains the following information for the IBM ARTICX.25 Interface Co-Processor PCI adapter (referred to as the PCIco-pr

Página 4 - First Edition (August 1996)

x X.25 Co-Processor PCI GTO

Página 5 - Statement of Limited Warranty

Chapter 1. Product DescriptionThe IBM ARTIC X.25 Interface Co-Processor PCI adapter (calledPCI co-processor adapter throughout this book), with su

Página 6

SpecificationsSizeLength: 181 mm (7.125 inches)Width: 17.5 mm (0.7 inches)Height: 127 mm (5.0 inches)Weight: 0.15 kg (0.33 lbs)Environment  Air

Página 7

Adapter Cable OptionsThe following adapter cables are available as options: X.21 Cable (FRU Part Number 16F1865)The X.21 cable is 3 meters (9.9 fe

Página 8

1-4 X.25 Co-Processor PCI GTO

Página 9 - Contents

Chapter 2. InstallationThis chapter lists the hardware and software/microcode requirementsand provides information for setting up and installing t

Página 10

Handling Static-Sensitive DevicesComponents for your PCI co-processor adapter can be damaged bystatic discharges. To prevent this damage, your PCI

Página 11 - About This Book

Step 1: Install the PCI Co-Processor Adapter in theSystem UnitUse the following steps as general information for installing your PCIco-processor ad

Página 13 - Highlights

11. Install the adapter by holding it by the top and firmly pressing itinto the expansion slot. 12. Align the slot in the card-retaining bracket w

Página 14 - Specifications

Step 2. Download the Diagnostics and OperatingSystem Support ProgramsDiagnostics and support programs for various operating systems areavailable wi

Página 15 - Adapter Cable Options

3. Choose the Transfer Protocol supported by yourcommunications software.4. View online or download the Readme/Instruction file.5. Follow the inst

Página 16

 IBM Realtime Control Microcode (ICAAIM.COM)ICAAIM.COM is the RAM-resident control program for the PCIco-processor adapter and is supplied with th

Página 17 - Chapter 2. Installation

Step 4: Connect the Optional Adapter CableUse the following steps to connect your adapter cable.Note: The optional adapter cables are described o

Página 18 - Installation Instructions

Chapter 3. Connector Information Pin NumbersThe 37-pin, D-shell, male connector on the PCI co-processor adapteris shown below.1201937The 15-pin, D

Página 19 - System Unit

Pin AssignmentsX.21 Connector InformationThe X.21 pin assignments for the 37-pin connector on the PCIco-processor adapter and the corresponding p

Página 20

X.21 bis (V.24) Connector InformationThe X.21 bis (V.24) pin assignments for the 37-pin connector on thePCI co-processor adapter and the correspond

Página 21 - System Support Programs

X.21 bis (V.35) Connector InformationThe X.21 bis (V.35) pin assignments for the 37-pin connector on thePCI co-processor adapter and the correspon

Página 22

Chapter 4. Problem DeterminationProceduresThis chapter contains step-by-step instructions that can help youdetermine if your PCI co-processor adap

Página 23 - Installation 2-7

IBM ARTIC X.25 Interface Co-ProcessorPCI Adapter Guide to OperationsIBM

Página 24

System Unit DiagnosticsFor details on performing the system unit diagnostics, see “ProblemDetermination Procedures” in the operating instructions

Página 25 - Pin Numbers

PCI Co-Processor Adapter Diagnostics TestNotes:1. You can test the PCI co-processor adapter with or without the37-pin wrap plug (shown in “Service

Página 26 - X.21 Connector Information

1. Set the Power switch on the system unit to Off.2. Insert your copy of the IBM Realtime Interface Co-Processor:Advanced Diagnostics diskette int

Página 27 - Assignments

Blank Screen, Blinking Cursor, or Non-DecipherableDataIf your screen is completely blank or has a blinking cursor ornon-decipherable data, do the f

Página 28

à ðIBM REALTIME INTERFACE CO-PROCESSORAND X.25 INTERFACE CO-PROCESSOR _____________________________________________________| | | | | | |PRESEN

Página 29 - Procedures

A screen similar to the following may appear.à ð _______________________________________________________________IBM REALTIME INTERFACE CO-PROCESSOR

Página 30 - System Unit Diagnostics

à ðIBM REALTIME INTERFACE CO-PROCESSORAND X.25 INTERFACE CO-PROCESSOR _____________________________________________________| | | | | | |PRESEN

Página 31

à ðIBM REALTIME INTERFACE CO-PROCESSORAND X.25 INTERFACE CO-PROCESSOR _____________________________________________________| | | | | | |PRESENT

Página 32 - IBM Realtime

If the switches are set correctly but the configuration shown on yourdisplay is wrong, replace the co-processor adapter associated withthe incorre

Página 33

DO YOU WANT TO TEST A CO-PROCESSOR ADAPTER SHOWNAS PRESENT ON THE DISPLAYED SCREEN?Note: A co-processor adapter is present if a “Y” appears in the

Página 34

Important Before using this information and the product it supports, be sure to read all theinformation in Appendix B, “Notices.”Before installi

Página 35 - Configuration Screen

FRU and Error Code TableUse the information in the following table to identify the failing FRU(field replaceable unit). Part numbers for FRUs are

Página 36 - Configuration Check

Interface TestA screen similar to the following is displayed for the interface test.à ðIBM REALTIME INTERFACE CO-PROCESSORAND X.25 INTERFACE CO-PR

Página 37

DO YOU WANT TO TEST AN INTERFACE (V.24, V.35, OR X.21)?Note: You can test the PCI co-processor adapter with or without the37-pin wrap plug (shown

Página 38 - Co-Processor Adapter Test

à ðIBM REALTIME INTERFACE CO-PROCESSORAND X.25 INTERFACE CO-PROCESSOR _____________________________________________________| | | | | | |PRESENT

Página 39

à ðIBM REALTIME INTERFACE CO-PROCESSORAND X.25 INTERFACE CO-PROCESSOR _____________________________________________________| | | | | | |PRESEN

Página 40 - FRU and Error Code Table

3. Insert your copy of the IBM Realtime Interface Co-Processor:Advanced Diagnostic diskette into the diskette drive, if previouslyremoved.4. When t

Página 41 - Interface Test

Co-Processor Adapter RemovalNote: The following steps are an example of co-processor adapterremoval. For specific adapter removal instructions, c

Página 42

8. Remove the co-processor adapter mounting screw. Problem Determination Procedures 4-19

Página 43

9. Grasp the co-processor adapter by the top corners and liftstraight up.Co-Processor Adapter ReplacementNote: The following steps are an example

Página 44

3. Press down firmly on the co-processor adapter to seat theconnector. 4. Install the co-processor adapter’s mounting screw.5. Install the system u

Página 45 - Advanced Diagnostic

Statement of Limited WarrantyThe warranties provided by IBM in this Statement of Limited Warranty apply only toMachines you originally purchase for

Página 46 - Co-Processor Adapter Removal

Service PartsAssembly 1: PCI Co-Processor Adapter12 Asm– Part Index Number Units Description1–1 55H4513 1 PCI co-processor adapter with memory–

Página 47

Assembly 2: Cables and Wrap Plugs Asm– Part Index Number Units Description2–1 16F1887 1 Cable Option X.21 (P/N 07F3151)–1 16F1888 1 Cable Option

Página 48

4-24 X.25 Co-Processor PCI GTO

Página 49

Appendix A. Special ConfigurationInformation Note: This appendix contains special configuration information for DOSand OS/2. If you are using ano

Página 50 - Service Parts

Adding an ICAPARM.PRM File Entry for the PCICo-Processor AdapterThe only time you need to add an entry to the ICAPARM.PRM file forthe PCI co-proce

Página 51

Example 1 — for One Co-Processor AdapterThe following example shows an ICAPARM.PRM file that can beused if you have one co-processor adapter instal

Página 52

9 and 10 System Unit Address to call an adapter reset. Use thevalues shown: 0Fh, E010h. (Not supported on the PCIco-processor adapter.)11 End-Reco

Página 53 - Information

Changing Your CONFIG.SYS FileIf OS/2 and Communications Manager/2 (CM/2) are being used, oneline of the CONFIG.SYS file must be modified (using a t

Página 54 - Co-Processor Adapter

A-6 X.25 Co-Processor PCI GTO

Página 55

Appendix B. NoticesReferences in this publication to IBM products, programs, or servicesdo not imply that IBM intends to make these available in a

Página 56

If you transfer a Machine to another user, warranty service is available to that user forthe remainder of the warranty period. You should give you

Página 57 - Changing Your CONFIG.SYS File

Safety InformationTurn Everything OFF.Attach signal cables toreceptacles.First, remove power cord fromoutlet.To DisconnectNote: In the UK, by law

Página 58

Notice to United Kingdom UsersThe United Kingdom Telecommunications Act 1984This apparatus is approved under General Approval number NS/G/1234/J/1

Página 59 - Appendix B. Notices

Required Electronic Emission and ConnectivityNoticesClass A Federal Communications CommissionStatementFederal Communications Commission (FCC)State

Página 60 - Safety Information

Industry Canada Compliance StatementThis Class A digital apparatus meets the requirements of theCanadian Interference-Causing Equipment Regulations

Página 61 - Notices B-3

Informationen in Hinsicht EMVG Paragraph 3, Abs. 2: Das Gerät erfüllt die Schutzanforderungen nach EN 50082-1 und EN 55022 Klasse A.EN 55022 Klass

Página 62

JapanThis equipment is in the 1st Class category (information equipmentto be used in commercial and/or industrial areas) and conforms tothe standa

Página 63 - Germany

Microcode Notice to CustomersMicrocode supplied by IBM for the ARTIC X.25 InterfaceCo-Processor PCI (PCI co-processor adapter) is protected bycopy

Página 64

Readers' Comments — We'd Like to Hearfrom You IBM ARTIC X.25 Interface Co-ProcessorPCI Adapter Guide to OperationsPart Number 77H4686Overa

Página 65 - Trademarks and Service Marks

NO POSTAGENECESSARYIF MAILED IN THEUNITED STATESBUSINESS REPLY MAILFIRST-CLASS MAIL PERMIT NO. 40 ARMONK, NEW YORKPOSTAGE WILL BE PAID BY ADDRESSEEInt

Página 67

THESE WARRANTIES GIVE YOU SPECIFIC LEGAL RIGHTS AND YOUMAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM JURISDICTIONTO JURISDICTION. SOME JURISDICTIONS D

Página 68 - BUSINESS REPLY MAIL

IBMPart Number: 77H4686Printed in U.S.A.77H4686

Página 69

vi X.25 Co-Processor PCI GTO

Página 70 - Printed in U.S.A

ContentsAbout This Book ....... ixRelated Publications . . . . . . . . . . . . . . . . . . . . . . . . . . ixChapter 1. Produ

Comentários a estes Manuais

Sem comentários