IBM System x3100 M4 23
SUSE LINUX Enterprise Server 11 for x86
SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T
Toshiba 4690 Operating System V6
VMware ESX 4.1
VMware vSphere 5.0 (ESXi)
VMware vSphere 5.1 (ESXi)
VMware vSphere 5.5 (ESXi)
See the IBM ServerProven® website for the latest information about the specific versions and service
levels supported and any other prerequisites:
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml
Physical and electrical specifications
Dimensions and weight - systems with a fixed power supply:
Height: 360 mm (14.2 in)
Width: 180 mm (7.1 in)
Depth: 480 mm (18.9 in)
Weight::
Minimum ship configuration: 10 kg (22.0 lb)
Maximum ship configuration: 13 kg (28.7 lb)
Dimensions and weight - systems with redundant hot-swap power supplies:
Height: 438.60 mm (17.27 in)
Width: 217.25 mm (8.56 in)
Depth: 569.11 mm (22.41 in)
Weight
Minimum ship configuration: 17.33 kg (38.21 lb)
Maximum ship configuration: 22.82 kg (50.31 lb)
Supported environment:
Temperature
Server on
10.0° to 35.0° C (50° to 95° F); altitude: 0 to 914.4 m (3,000 ft)
10.0° to 32.0° C (50° to 89.6° F); altitude: 914.4 m (3,000 ft) to 2,133.6 m (7,000 ft)
Server off
10.0° to 43.0° C (50° to 109.4° F); maximum altitude: 2,133.6 m (7,000 ft)
Shipping
-40° to 60° C (-40° to 140° F)
Relative humidity: 8 to 80%
Maximum altitude: 2,133.6 m (7,000 ft)
Electrical:
430 watt power supply:
100 - 127 (nominal) V ac; 50 - 60 Hz; 6.0 A (maximum)
200 - 240 (nominal) V ac; 50 - 60 Hz; 3.0 A (maximum)
Input kilovolt-amperes (kVA) (approximately)
Minimum configuration: 0.100 kVA
Maximum configuration: 0.506 kVA