Página 1 - ERserver

iSeriesNetworkingiSeries Communications ManagementERserver

Página 2

4 Version 5

Página 3 - ER s e r v e r

v Frame relay direct network: Allows data that uses SNA, TCP/IP, or IPX communications over aframe-relay network to move at speeds of up to 2.048 Mbps

Página 4

Note: SDLC supports traditional AS/400 communication protocols, such as APPC, but does not supportTCP/IP.X.25 networkX.25 is a Telecommunications Stan

Página 7

Printed in U.S.A.

Página 8 - 2 Version 5

Chapter 2. Configuring AS/400 for communicationsFollow these steps to configure your AS/400:1. Depending on the type of hardware you have, you may nee

Página 10 - 4 Version 5

Chapter 3. Optimizing communications performanceMany factors can affect the performance of AS/400 application programs. To achieve the best performanc

Página 11 - Creating a line description

v For interactive environments, keep line use below 30% to maintain predictable and consistent responsetimes. Exceeding 50% line use usually slows dow

Página 12 - 6 Version 5

processing a larger frame is only slightly more than the amount needed to process a smaller frame. Ifyou use larger frames to transfer a single system

Página 13

parameter value on one system should never have a greater value than the LANMAXOUT parametervalue on the other system. The parameter values of the sen

Página 14 - 8 Version 5

v Mix interactive and batch jobs on a wide area network linev Performance considerations for AnyNet communicationsv SubsystemsConsiderations for subsy

Página 15

Example: Communications subsystem configuration1. Create a duplicate of QCMN:CRTDUPOBJ OBJ(QCMN) FROMLIB(QSYS) OBJTYPE(*SBSD) TOLIB(MYLIB) NEWOBJ(MYCM

Página 16 - 10 Version 5

Example: Interactive subsystem configuration1. Create a subsystem description:CRTSBSD SBSD(MYLIB/MYINTER) POOLS((1 *BASE) (2 *INTERACT))2. Create a cl

Página 18 - 12 Version 5

v Change the request/response unit size to a lower value for the large transfer. This parameter settingoptimizes response time at the expense of large

Página 19

are written for one type of network protocol to run over a different type of network protocol. For example,without AnyNet, your choice of application

Página 20 - 14 Version 5

For more information about creating subsystems, see the Work Management book.16 Version 5

Página 21 - Subsystems

Chapter 4. Communications applicationsCommunications applications that are used in an APPC (advanced program-to-program) environment arealso available

Página 22 - 16 Version 5

v Using larger sends for a given large transfer (record sizes) provides a higher application data rate anddecreases CPU time. With the larger record s

Página 23

Performance considerations for Common Programming InterfaceCommunicationsYou can use Common Programming Interface Communications (CPI Communications)

Página 25 - Communications

Chapter 5. Communicating with host systemsYou can configure the AS/400 system to communicate with a host system by matching AS/400parameters.Another o

Página 26 - 20 Version 5

AS/400 PromptAS/400ParameterHost DefinitionStatement Host ParameterLocal adapter address ADPTADR PATH DIALNOHost DIALNO parameter is a concatenation o

Página 27

Matching AS/400 controller description parameters for a host systemYou must match host system communications configuration parameters with AS/400 valu

Página 28 - 22 Version 5

iSeriesNetworkingiSeries Communications ManagementER s e r v e r

Página 29

AS/400 PromptAS/400ParameterHost DefinitionStatement Host ParameterMaximum frame size MAXFRAME GROUP MAXDATAValues specified for each system must matc

Página 30 - 24 Version 5

v Use the following table for the device description parameter.AS/400 PromptAS/400ParameterHost DefinitionStatement Host ParameterLocal location name

Página 31

AS/400 PromptAS/400ParameterHost DefinitionStatement Host ParameterMode descriptionnameMODD MODEENT LOGMODEAS/400 mode description name specified on t

Página 32 - 26 Version 5

Example 2: AS/400 to host system over a token-ring line.This diagram shows the AS/400 values that need to match the VTAM values when you use a token-r

Página 33

Example 3: AS/400 system for DLUR support with the host system.28 Version 5

Página 34 - 28 Version 5

This diagram shows the AS/400 values that need to match the VTAM values when you use AS/400 DLURand VTAM.Example 4: AS/400 with APPN connection to VTA

Página 35

30 Version 5

Página 36 - 30 Version 5

Configuring dependent LU requester (DLUR)Dependent LU Requester (DLUR) allows dependent secondary logical units (LU 0, 1, 2, and 3) an entrypoint into

Página 37

Note: This must match the VTAM LU name with the corresponding local location address(LOCADDR) on VTAM.For more information on DLUR see, Dependent LU R

Página 38 - 32 Version 5

Chapter 6. Communicating with a remote AS/400 systemUsing advanced program-to-program communications (APPC), you can configure the AS/400 system tocom

Página 39

© Copyright International Business Machines Corporation 1998, 2001. All rights reserved.US Government Users Restricted Rights – Use, duplication or di

Página 40 - 34 Version 5

AS/400 PromptAS/400ParameterRemote AS/400Parameter NotesConnection initiation CNNINIT CNNINIT If X.25 DCE support is specified (X25DCE(*YES)) foreithe

Página 41

AS/400 PromptAS/400ParameterRemote AS/400Parameter NotesX.25 DCE support X25DCE X25DCE If X.25 DCE support is used (X25DCE(*YES)), only oneof the AS/4

Página 42 - 36 Version 5

AS/400 PromptAS/400ParameterRemote AS/400Parameter NotesExchange identifier EXCHID EXCHID If used, the local AS/400 controller description EXCHIDmust

Página 43

AS/400 PromptAS/400ParameterRemote AS/400Parameter NotesLCLLOCNAME RMTLOCNAME For systems not using APPN (APPN(*NO) specified forthe controller and de

Página 44 - 38 Version 5

This example shows the matching parameters between an AS/400 connecting to another AS/400 that usesX.25.Example 2: AS/400 to AS/400 using SDLC38 Versi

Página 45

This example shows the matching parameters between an AS/400 connecting to another AS/400 that usesSDLC.Example 3: AS/400 to AS/400 using one-way auto

Página 47

Chapter 7. Communicating with remote workstationcontrollersYou can configure the AS/400 system to communicate with another AS/400 system, a non-AS/400

Página 48 - 42 Version 5

AS/400Prompt AS/400 Parameter5494AS/400Value 5494 Value NotesField SubfieldLocaladapteraddressADPTADR H1 5 - - Values specified in the AS/400line desc

Página 49

AS/400Prompt AS/400 Parameter5494AS/400Value 5494 Value NotesField SubfieldLink type LINKTYPE AA - *LAN 4 5494 configuration values mustmatch the valu

Página 50 - 44 Version 5

ContentsPart 1. Getting started with AS/400 communications ...1Chapter 1. Print this topic ...3Chapter 2. Configu

Página 51

Matching AS/400 parameters for a 5494 connected by EthernetYou must coordinate communications configuration parameters between AS/400 and the 5494 con

Página 52 - 46 Version 5

v To automatically connect the AS/400 to a 5494 controller, you can use the automatic remote controller(QAUTORMT) system value.v To manually connect t

Página 53

Matching AS/400 parameters for a 5494 connected by frame relayYou must coordinate the communications configuration parameters between AS/400 and the 5

Página 54 - 48 Version 5

v IBM 5494 Remote Control Unit Planning Guide, GA27-3936v IBM 5494 Remote Control Unit User’s Guide, GA27-3852AS/400Prompt AS/400 Parameter5494AS/400V

Página 55

The following diagram shows the AS/400 parameters and 5494 parameters that need to match when youuse frame relay.Matching AS/400 parameters for a 5494

Página 56 - 50 Version 5

For more information about configuring the 5494, see these books:v IBM 5494 Remote Control Unit Planning Guide, GA27-3936v IBM 5494 Remote Control Uni

Página 57

AS/400PromptAS/400Parameter5494AS/400 Value 5494 Value NotesField SubfieldRemotelocationnameRMTLOCNAME 12 - - - Values specified for the AS/400CRTCTLR

Página 58 - 52 Version 5

Chapter 7. Communicating with remote workstation controllers 51

Página 59

Matching AS/400 parameters for a 5494 connected by X.21You must coordinate communications configuration parameters between AS/400 and the 5494 remotec

Página 60 - 54 Version 5

AS/400PromptAS/400Parameter5494AS/400 Value 5494 Value NotesField SubfieldLink type LINKTYPE AA - *X21 4 5494 configuration values mustmatch the value

Página 61

Matching AS/400 parameters for a 5494 connected by frame relay ...46Matching AS/400 parameters for a 5494 connected by SDLC ...4

Página 62 - 56 Version 5

Matching AS/400 parameters for a 5494 connected by X.25You must coordinate communications configuration parameters between the AS/400 and the 5494cont

Página 63

v IBM 5494 Remote Control Unit User’s Guide, GA27-3852AS/400PromptAS/400Parameter5494AS/400Value 5494 Value NotesField SubfieldDefaultpacket sizeDFTPK

Página 64 - 58 Version 5

AS/400PromptAS/400Parameter5494AS/400Value 5494 Value NotesField SubfieldStationaddressSTNADR 2 - - - Values specified in the AS/400controller descrip

Página 65

Chapter 7. Communicating with remote workstation controllers 57

Página 66 - 60 Version 5

Matching AS/400 parameters for 3x74 controllerYou must match the AS/400 configuration parameters with some configuration questions and sequencenumbers

Página 67

AS/400PromptAS/400Parameter3174ConfigurationQuestions NotesLocal adapteraddressADPTADR 107 Token-Ring Network Address of the GatewayIf the AS/400 syst

Página 68 - 62 Version 5

AS/400PromptAS/400Parameter3174ConfigurationQuestions NotesLocal networkaddressNETADR 423 Host DTE Address (HNAD)For X.25 SVCs, the network address sp

Página 69

AS/400PromptAS/400Parameter3274SequenceNumber NotesConnectionnumberCNNNBR 411 3274 DTE AddressFor X.25 SVCs, the connection number specified on theCRT

Página 70 - 64 Version 5

The following diagram shows the AS/400 parameters and 3174 parameters that need to match when youuse token-ring.Matching AS/400 parameters for finance

Página 71

AS/400 PromptAS/400Parameter 4700 Macro 4700 ParameterConnectiontypeCNN COMLINK ACBFor SDLC finance communications, if the line is switched(CNN(*SWTPP

Página 72 - 66 Version 5

Part 1. Getting started with AS/400 communicationsThe AS/400 is an extremely versatile system for networking technologies, supporting a broad range of

Página 73

AS/400 PromptAS/400Parameter 4700 Macro 4700 ParameterMaximumframe sizeMAXFRAME COMLINK CNLValue specified for the 4700 CNL parameter must becoordinat

Página 74 - 68 Version 5

AS/400 PromptAS/400ParameterFBSSConfigurationDisplay FBSS PromptLAN adapter address ADPTADR Token RingCommunicationsPC addressIf the AS/400 system use

Página 75

AS/400 PromptAS/400ParameterFBSSConfigurationDisplay FBSS PromptExchange identifier EXCHID SDLCCommunicationsIdentification block and Identification n

Página 76 - 70 Version 5

Example: Connecting AS/400 to a finance networkConfiguration parameters must be coordinated when you connect an AS/400 system to a 4701 financecontrol

Página 77

To configure an AS/400 to a retail controller, see the following.v “Matching AS/400 parameters for 3651 retail controllers”v “Matching AS/400 paramete

Página 78 - 72 Version 5

AS/400 PromptAS/400Parameter3651 DefinitionStatement 3651 ParameterSSCP identifier SSCPID QFHOST SSCPID3651 SSCPID parameter must match the SSCPIDpara

Página 79

SDLCLIN Bit Bit ValueAS/400 Parameterand Value Notes2 and 3 00 SWITCHED(*YES)CNN(*SWTPP)Bit 2: Specify 1 if using nonswitchedcommunications, or 0 if u

Página 80 - 74 Version 5

AS/400PromptAS/400Parameter3684DefinitionStatement 3684 ParameterExchangeidentifierEXCHID QVSFGLNK SENDID3684 SENDID parameter must match the last 5 d

Página 81

The default value for each bit is underlined in the Bit Value column.To configure the AS/400 to a 3684 retail controller, use the following table.LINE

Página 82 - 76 Version 5

AS/400 Prompt AS/400 Parameter 4680 Line ParameterConnection type CNN 4680 CONNECTION TYPE parameter value must be coordinated withthe values specifie

Página 83

2 Version 5

Página 84 - 78 Version 5

AS/400 Prompt AS/400 Parameter 4680 Link ParameterLocal locationaddressLOCADR 4680 SESSION ADDRESS parameter must match the LOCADRparameter specified

Página 85

AS/400 PromptAS/400ParameterRIPSS ConfigurationDisplay RIPSS PromptExchange identifier EXCHID SDLC Server Data Block number (hex) and XID (hex)For SDL

Página 86 - 80 Version 5

Example 2: AS/400 to 4690 PEER connection over token-ring network76 Version 5

Página 87

Chapter 7. Communicating with remote workstation controllers 77

Página 89

Chapter 8. Troubleshooting communications problemsIf you suspect you have a problem with communications connectivity, the AS/400 system provides a set

Página 90 - 84 Version 5

Displaying the Product Activity Log to solve communication problemsThe Print Error Log and the Product Activity Log provide you with important informa

Página 91

QPASVRPTarget 5250 display station pass-through primary server job. This job log is for target pass-throughcommunications functions.QPASVRSTarget 5250

Página 92 - 86 Version 5

System service tools and communication problemsYou may sometimes need to obtain an error log printout or communications trace data that your IBMservic

Página 93

1-16000 KThe valid range for the maximum number of bytes used for storing collected trace information.Trace fullSpecifies whether new trace records re

Página 94 - 88 Version 5

Chapter 1. Print this topicTo view or download the PDF version, select Getting started with AS/400 communications (about 721 KBor 110 pages).To save a

Página 95 - HPR architecture option sets

You can also sort the WRKPRB display by the date the problem was entered into the log.Note: Use the WRKPRB command for the menu options, additional pr

Página 96 - What is TCP/IP

Refer to Table 13 for an explanation on reason codes for failed program start requests.Table 1. Reason Codes for Rejected Program Start RequestsReason

Página 97 - Ethernet networks

Table 1. Reason Codes for Rejected Program Start Requests (continued)ReasonCode Reason Description901 Program initialization parameters are not valid.

Página 98 - Wireless network

Chapter 9. Networking conceptsIf you would like more information on networking topics, review the following:v Advanced Peer-to-Peer Networking support

Página 99 - Frame relay networks

Advanced program-to-program communicationsAdvanced program-to-program communications (APPC) is data communications support that allowsprograms on an A

Página 100 - 94 Version 5

v Sendv ReceiveAt the primary end of the pipe is a Dependent LU Server (DLUS). At the secondary end of the pipe is aDependent LU Requester (DLUR). DLU

Página 101 - X.21 network

Internetwork Packet Exchange support is the AS/400 implementation of the NetWare communicationprotocols. These protocols include IPX, Sequenced Packet

Página 102 - 96 Version 5

Chapter 10. Common networking standardsThese topics introduce the types of common networking standards that are supported by the AS/400system. See the

Página 103

Half-duplex EthernetGenerally, multiple stations in an Ethernet network show a single data path. Therefore, only onestation may transmit data at a tim

Página 104 - Printed in U.S.A

the AS/400 wireless LAN adapter and remote stations. Remote stations can be PTCs that are running5250 emulation or LAN-connected systems that are equi

Comentários a estes Manuais