IBM H80 Manual do Utilizador Página 105

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 230
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 104
SCSI Utilities
SCSI Utilities allow you to set delay times for the SCSI hard disk spin-up and to set
SCSI IDs for SCSI controllers installed in the system.
à ð
SCSI Utilities
1. Harddrive Spin Up Delay
2. Change SCSI Id
.--------.
| X=Exit |
--------'
===>
á
ñ
Using the Harddrive Spin Up Delay option allows you to change the spin up delay
time for SCSI hard disk drives attached to your system. Spin up delay values can be
entered manually, or you can use a default setting (two seconds). All values are
measured in seconds.
Attention: Setting the value lower than the default can prevent successful booting
because the system power handling capabilities might be exceeded. If the system
no longer boots after setting this value, access this utility again and increase the
value. It is also possible that adding disk drives can cause similar symptoms.
Changing this value changes the surge current requirements on the system. As you
increase the value, the surge current requirements on the system are decreased.
Select Console
Select this option to define which display is used by the system for system
management. If no console is selected, the console defaults to Serial Port 1.
à ð
Press  to select this console
as the active console
á
ñ
Chapter 4. Using System Management Services 89
Vista de página 104
1 2 ... 100 101 102 103 104 105 106 107 108 109 110 ... 229 230

Comentários a estes Manuais

Sem comentários