IBM H80 Manual do Utilizador Página 58

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 230
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 57
Enable supplemental restart policy - The default setting is NO. If set to
YES, the service processor restarts the system when the system loses
control as detected by service processor surveillance, and either:
The Use OS-Defined restart policy is set to NO.
OR
The Use OS-Defined restart policy is set to YES, and the operating
system has NO automatic restart policy.
Refer to “Service Processor Reboot/Restart Recovery” on page 64.
Call-Out before restart (Enabled/Disabled) - If a restart is necessary due to
a system fault, you can enable the service processor to call out and report
the event. This option can be valuable if the number of these events
becomes excessive, signalling a bigger problem.
Power-On System
Allows immediate power-on of the system. For other power-on methods, see
“Powering On the System” on page 4.
Power-Off System
Allows the user to power-off the system.
Enable/Disable Fast System Boot
Allows the user to select the IPL type, mode, and speed of your boot capabilities.
Attention: Selecting the fast IPL results in several diagnostic tests being skipped
and a shorter memory test being run.
42 RS/6000 Enterprise Server Model H80 Series User's Guide
Vista de página 57