Ibm TOTAL STORAGE DS8000 Manual do Utilizador Página 180

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 374
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 179
Action
Delete the ranks on the array or wait until the format completes, and then resubmit
the task.
CMUN02041E SOURCE Unable to create logical subsystem: device type
must be CKD
Explanation
The specified device type must be count-key-data.
Action
Specify a CKD device type, and then resubmit the task. If the problem persists,
contact IBM technical support for assistance.
CMUN02042E SOURCE Operation failure: configuration already exists
Explanation
You are attempting to create a configuration that already exists.
Action
Specify a unique configuration, and then resubmit the task.
CMUN02043E SOURCE Operation failure: internal database not open
Explanation
The storage management console server reports a storage unit microcode-level
error.
Action
Contact IBM technical support for assistance.
CMUN02044E SOURCE Operation failure: unable to allocate memory
Explanation
The storage management console server reports a storage unit microcode-level
error.
Action
Contact IBM technical support for assistance.
CMUN02045E SOURCE Operation failure: unable to allocate memory
Explanation
The storage management console server reports a storage unit microcode-level
error.
160 IBM TotalStorage DS8000: Messages Reference
Vista de página 179
1 2 ... 175 176 177 178 179 180 181 182 183 184 185 ... 373 374

Comentários a estes Manuais

Sem comentários