CMUN03113E SOURCE Operation failure: CKD base required
Explanation
A count-key-data base device is required for this operation. A count-key-data alias is
specified.
Action
Specify a CKD base device, and then resubmit the task.
CMUN03114E SOURCE Unable to establish FlashCopy with fast reverse
restore: previous FRR
Explanation
A FlashCopy with fast reverse restore (FRR) cannot be established if a FlashCopy
with FRR is still in progress or if one has recently completed.
Action
Wait, and then resubmit the task. If the problem persists, contact IBM technical
support for assistance.
CMUN03115E SOURCE Performance statistics cannot be accumulated:
LSS not configured
Explanation
A logical subsystem must be configured before performance statistics can be
requested. No logical subsystem is configured.
Action
Configure the logical subsystem, and then resubmit the task.
CMUN03116E SOURCE Performance statistics cannot be accumulated:
resource not configured
Explanation
The rank, extent pool, or I/O port to be queried for performance statistics is not
configured.
Action
Configure the resource, and then resubmit the task.
CMUN03117E SOURCE Unable to establish FlashCopy or Remote Mirror
and Copy pair. A FlashCopy initialization is in progress.
Explanation
The pair cannot be established until intialization completes.