CMUN06026E SOURCE Operation failure: an external utility does not
run
Explanation
The utility might not run for one of the following reasons:
v The utility invoked by the service advisor does not exist or the utility has been
moved.
v You are not invoking the utility from the storage management console.
v The storage management console server software installation failed.
Action
1. Ensure that the PUTTY command is installed properly and its location is
specified in the PATH environment variable.
2. Ensure that %MR1750_SM_HOME%\bin is specified in the PATH environment
variable.
3. Run the command from the storage management console with administrator
authority.
4. If the problem persists, then re-install the storage management console server
software.
5. If the problem still persists, contact IBM technical support for assistance.
CMUN06027E SOURCE Operation failure: thread interupted
Explanation
The storage management console server reports an internal service advisor error.
The program is interrupted for an unknown reason.
Action
Contact IBM technical support for assistance.
CMUN06028E SOURCE Operation failure: timeout
Explanation
The storage management console server reports an internal service advisor error.
The program times out before it completes.
Action
This might be a temporary problem. Resubmit the task. If the problem persists,
contact IBM technical support for assistance.
CMUN06029E SOURCE Operation failure: unknown operating system
Explanation
The storage management console server reports an internal service advisor error.
An unknown operating system is detected.
Chapter 7. DS storage management console server messages 309