Checkpoint
(hex)
Description Repair Action
E602 SSA PCI adapter
open firmware has
started.
1. Replace the adapter.
2. See “Unresolved problems” on page 3-26
E603 SSA PCI adapter
BIST has completed
with an error.
1. Replace the adapter.
2. See “Unresolved problems” on page 3-26
E604 SSA PCI adapter
BIST and
subsequent POSTs
have completed
successfully.
1. Replace the adapter.
2. See “Unresolved problems” on page 3-26
E605 SSA PCI adapter
BIST has completed
successfully but the
subsequent POSTs
have failed.
1. Replace the adapter.
2. See “Unresolved problems” on page 3-26
E60E SSA PCI adapter
open firmware about
to exit (no stack
corruption)
1. Replace the adapter.
2. See “Unresolved problems” on page 3-26
E60F SSA PCI adapter
open firmware has
run unsuccessfully.
1. Replace the adapter.
2. See “Unresolved problems” on page 3-26
E6FF SSA PCI adapter
open firmware about
to exit ( with stack
corruption ).
1. Replace the adapter.
2. See “Unresolved problems” on page 3-26
Unresolved problems: Go to “MAP 1540: Minimum Configuration” on page
2-17 for any of the following conditions:
A 4-digit code in the range of “E100” through “EFFF” is displayed on the operator
panel display but is not listed in the table that lists firmware checkpoints on page
3-14.
A 4-digit code is displayed and is listed in the table that lists firmware
checkpoints on page 3-14, but there are no repair actions or FRUs listed for the
code.
All of the FRUs listed in repair actions have been replaced, and the problem has
not been corrected.
3-26 7046 Model B50 Service Guide