IBM PPC440X5 Manual do Utilizador Página 356

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 590
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 355
maclhwu
Multiply Accumulate Low Halfword to Word Modulo Unsigned
PPC440x5 CPU Core User’s Manual Preliminary
Page 356 of 589
instrset.fm.
September 12, 2002
maclhwu
Multiply Accumulate Low Halfword to Word Modulo Unsigned
prod
0:31
(RA)
16:31
× (RB)
16:31
unsigned
temp
0:32
prod
0:31
+ (RT)
(RT)
temp
1:32
The low-order halfword of RA is multiplied by the low-order halfword of RB. The unsigned product is summed
with the contents of RT and RT is updated with the low-order 32 bits of the unsigned sum.
Registers Altered
•RT
CR[CR0] if Rc contains 1
XER[SO, OV] if OE contains 1
Architecture Note
This instruction is implementation-specific and programs which use this instruction may not be portable to
other PowerPC Book-E implementations. See Instruction Set Portability on page 250.
maclhwu RT, RA, RB OE=0, Rc=0
maclhwu. RT, RA, RB OE=0, Rc=1
maclhwuo RT, RA, RB OE=1, Rc=0
maclhwuo. RT, RA, RB OE=1, Rc=1
4 RT RA RB OE 396 Rc
0 6 11 16 21 22 31
Vista de página 355